Type C conductive FIBC bags
Type C FIBC bags have conductive threads woven through the fabric in a connected grid that ends at a ground tab, so static charge is carried off to earth while the bag fills and empties. They only work when that tab is clamped to a verified ground for the whole operation; an ungrounded Type C bag is unsafe and must never be filled.
| Static type | Type C, conductive; must be grounded during filling and discharge |
|---|---|
| Fabric | Woven polypropylene with interconnected conductive threads |
| Ground tab | One or more labelled grounding points sewn to the bag |
| Top | Spout top, so the fill connection can be closed |
| Bottom | Discharge spout |
| Loops | Four |
| Liner | Only a liner the bag maker states is compatible with Type C use |
| SWL range | Commonly 1,000 to 3,000 lb |
| Safety factor | 5:1 single trip; 6:1 multi trip where rated |
Good for
- Combustible powders where your hazardous-area assessment calls for Type C
- Filling near flammable solvent vapours, where the site assessment permits it
- Plants that already run grounding clamps or ground-monitoring units
- Resin, chemical and pigment powders that charge as they flow
Not for
- Any site that cannot guarantee a ground connection at every fill and discharge
- Operators who have not been trained on the grounding step
- Use with an ordinary film liner the maker has not cleared for Type C
- Bags with a missing, torn or painted-over ground tab
Put this in the request
- The product, and what your hazardous-area assessment says about it
- Whether flammable vapours or gases can be present at filling or emptying
- Your grounding equipment: clamp type, cable, any monitoring unit
- SWL, base and height
- Top and bottom spout sizes
- Liner needed, and if so the type the bag maker approves for Type C
- 5:1 or 6:1, quantity and delivery ZIP
What makes Type C FIBC bags conductive
Polypropylene is an insulator. As powder slides into or out of a plain bag, charge builds on the fabric and the product with nowhere to go. A Type C bag weaves conductive threads into the cloth, usually as a grid, and joins every section of that grid, across the seams, to a tab on the outside. Clamp the tab to earth and the charge drains away instead of building.
That last step is the whole design. Type B fabric works by limiting the kind of discharge the surface can produce and is never grounded. Type D fabric dissipates charge on its own without a ground. Type C does neither by itself; it is a conductor that needs a path to earth.
A plain polyethylene liner can put an insulating layer between the product and the conductive fabric, which undercuts the protection. If the product needs a liner, use one the bag maker has tested or approved as compatible with that Type C bag, and say so in the request so the pair is quoted together.
Type C FIBC grounding, step by step
Treat grounding as part of the fill, not something done after. Your site's procedure governs; this is the general shape of it.
- Look the bag over: label legible, ground tab present and undamaged, no cuts, scorch marks or snagged yarns in the fabric
- Hang the bag, then attach the grounding clamp to the tab before any product moves
- Check continuity from the tab to earth with a meter or the site's ground-monitoring unit, as the bag maker's documents describe
- Fill with the clamp attached; do not remove it to adjust the bag
- Close the top, and only then release the clamp
- Repeat at discharge: clamp first, check, empty fully, unclamp last
Never fill a Type C bag ungrounded
An ungrounded conductive bag is worse than a plain one. The threads collect charge from the whole bag surface and can release it as a single spark to a nearby object or person. That is precisely the event the bag exists to prevent.
So a missing tab, a clamp that has slipped, a cable worn through or a reading that fails all mean the same thing: stop, fix the connection, and recheck before product moves again. Many plants interlock the filler to a ground monitor so it will not start until the circuit proves good. Supervisors who audit that interlock regularly, and log each failed reading, catch worn hardware long before an incident.
The test methods and requirements for these bags sit in IEC 61340-4-4. Check that standard, NFPA 77 for your general static-control practice, and the bag maker's documents, and follow your site's hazardous-area assessment. We do not set those limits; we match the bag to them.
Shipping and storing conductive bags
Type C bags fold and bale like any other FIBC and ship on wrapped pallets, LTL or full truck depending on how many you need. Keep the bales dry and out of sunlight. When a bale is opened, check that tabs are intact and labels readable; a bag with a damaged tab goes aside and is not used.
Rough handling on a dock can kink or snap conductive yarns where nobody sees it, so careless unloading costs more here than with plain fabric. Forks pushed into a bale, a pallet dropped from a tailgate or bales left under a leaking roof all justify a closer look and a continuity check on a sample before the lot goes to production.
Your grounding kit at the filling station
The hardware is modest but it has to be right. A heavy-duty clamp with hardened jaws bites the tab firmly. A flexible, insulated, preferably coiled cable runs to a copper busbar or another point your electrician has confirmed is bonded to earth. Metal parts of the fill head, hopper, scale and frame are bonded too, because an isolated chute can charge up on its own.
Ground-monitoring units add a light or a relay that proves the circuit and can stop the feeder if the clamp falls off mid-fill. Whatever you use, inspect cables for fraying, clean corroded jaws, and write the checks into the operators' shift routine. Training matters as much as equipment: a newcomer who does not know why the clamp is there is the person most likely to skip it.
The bag is only one source of charge. People walking on insulating floors, plastic scoops, unbonded drums and dry winter air all add to the hazard. General static-control practice covers personnel grounding, such as dissipative footwear and floors, alongside the bag; your safety engineer decides which of those your area requires.
Type C, Type B or Type D
The choice belongs to your hazardous-area assessment, not to price. Plants often favour Type D where operators rotate frequently or grounding discipline is hard to sustain, and keep Type C where clamps and monitors are already installed and audited. As a broad guide, here is how the three static types differ in use.
| Type | How it controls static |
|---|---|
| Type B | Limits surface discharges; not grounded; dry flammable powders only, no flammable vapours |
| Type C | Conductive threads carry charge to earth; must be grounded every time |
| Type D | Dissipates charge without a ground connection |
Questions
Where do I clamp the ground on a Type C bag?
To the labelled ground tab, or tabs, sewn on the bag. Clamp only there, and make the connection before filling starts. Biting into a random patch of cloth or a lifting loop proves nothing about continuity.
Can I skip grounding if the product is only mildly combustible?
No. If a Type C bag is used, it is grounded. If grounding cannot be guaranteed, discuss a different static type against your hazardous-area assessment.
How do I check a Type C bag is working?
Confirm continuity from the ground tab to earth with a meter or a monitoring unit, as the bag maker's documents set out, before product moves.
Are used Type C bags available?
We do not offer used bags for static-sensitive loads. Conductive bags for those jobs are supplied new.
Request type c conductive fibc bags
The spec from the label, the count and the ship-to ZIP. We confirm the spec, build the load and come back with the freight and the delivery window.